Data Channel Usage
How does the type of connected ZETSENSOR affect data channel usage of the measuring line to which it is connected?
Effect of the Digital Sensor Type And Selected Data Output Frequency On Usage (In Percent) Of Data Channel With Rs485 Interface For Data Rates 19.2, 57.6 and 115.2 Kbps | ||||
---|---|---|---|---|
Module type | Frequency of data output (Hz) | Data rate of RS 485 interface (Kbps) | ||
19.2 | 57.6 | 115.2 | ||
ZET7010, ZET7010 DS, ZET7010 DT, ZET7012-A, ZET7012-I |
5 10 25 50 125 |
2.4% 4.8% 12% 24% 60% |
0.8% 1.6% 4% 8% 20% |
0.4% 0.8% 2% 4% 10% |
ZET7020 | 1 4 |
0.48% 1.92% |
0.16% 0.64% |
0.08% 0.32% |
ZET7021 | 10 62 |
4.8% 28.8% |
1.6% 9.6% |
0.8% 4.8% |
ZET7050, ZET7051, ZET7060-E, ZET7060-S |
10 | 4.80% | 1.60% | 0.80% |
ZET7052, ZET7061 |
10 | 14.40% | 4.80% | 2.40% |
ZET7054 | 1 10 100 500 |
0.96% 9.6% 96% unrealizable |
0.32% 3.2% 32% unrealizable |
0.16% 1.6% 16% 90% |
ZET7060-G, ZET7090 |
10 | 9.60% | 3.20% | 1.60% |
ZET7060 | 1 10 50 100 200 |
0.48% 4.8% 24% 48% 96% |
0.16% 1.6% 8% 16% 32% |
0.08% 0.8% 4% 8% 16% |
ZET7080-I, ZET7080-V |
10 100 400 |
4.8% 48% unrealizable |
1.6% 16% 64% |
0.8% 8% 32% |
Effect Of the Digital Sensor Type And Selected Data Output Frequency On Usage (In Percent) Of Data Channel With CAN Interface For Data Rates 100, 300 and 1000 Kbps | ||||
---|---|---|---|---|
Module type | Frequency of data output (Hz) | Data rate of CAN interface (Kbps) | ||
100 | 300 | 1000 | ||
ZET7110, ZET7110 DS, ZET7110 DT, ZET7112-A, ZET7112-I |
5 10 25 50 125 |
0.5% 1% 2.5% 5% 12.5% |
0.17% 0.34% 0.84% 1.67% 4.17% |
0.05% 0.1% 0.25% 0.5% 1.25% |
ZET7111, ZET7111-L |
50 250 625 1,250 |
5% 25% 62.5% unrealizable |
1.7% 8.4% 20.84% 41.7% |
0.5% 2.5% 6.25% 12.5% |
ZET7120 | 1 4 |
0.1% 0.4% |
0.04% 0.14% |
0.01% 0.04% |
ZET7121 | 10 50 |
1% 5% |
0.34% 1.7% |
0.1% 0.5% |
ZET7140-S | 50 100 500 1,000 5,000 10,000 |
5% 10% 50% 100% unrealizable unrealizable |
1,7% 3,4% 16,7% 33,4% unrealizable unrealizable |
0,5% 1% 5% 10% 50% 100% |
ZET7140-E | up to 2,000 | depends on frequency of recorded events | ||
ZET7140-R, ZET7160-E |
1 10 100 |
0.1% 1% 10% |
0.04% 0.34% 3.4% |
0.01% 0.1% 1% |
ZET7141 | up to 2,000 | depends on frequency of recorded events | ||
ZET7150 | 10 100 400 |
1% 10% 40% |
0.34% 3.4% 13.4% |
0.1% 1% 4% |
ZET7151 BC 314 |
10 500 1,000 2,000 4,000 8,000 12,000 |
1% 50% 100% unrealizable unrealizable unrealizable unrealizable |
0.34% 16.7% 33.4% 66.7% unrealizable unrealizable unrealizable |
0.1% 5% 10% 20% 40% 80% unrealizable |
ZET7152 | 10 800 |
3% unrealizable |
1% 80% |
0.3% 24% |
ZET7154 | 1 10 100 500 |
0.2% 2% 20% 100% |
0.07% 0.67% 6.7% 33.4% |
0.02% 0.2% 2% 10% |
ZET7160 | 100 500 1,000 1,500 2,000 |
10% 50% 100% unrealizable unrealizable |
3.4% 16.7% 33.4% 50% 67.7% |
1% 5% 10% 15% 20% |
ZET7160-S, ZET7160-RS, ZET7160-R, ZET7191, ZET7175, ZET7178 |
10 | 1% | 0,34% | 0,10% |
ZET7160-G, ZET7190, ZET7190-R |
10 | 2% | 0.67% | 0.20% |
ZET7161 | 10 | 3% | 1% | 0.30% |
ZET7180-I, ZET7180-V |
10 100 400 |
1% 10% 40% |
0.34% 3.4% 13.3% |
0.1% 1% 4% |
Data rate between fragments of measuring network through a segment created on a radio channel with ZET 1772M and ZET 7152S modules – not more than 600 counts per second.
Data rate through GSM channel created with ZET 7177 module is not more than 200 counts per second.