Digital gauge pressure ZET 7012-I VER.2

  • Integrated primary transducer
  • Explosion-proof product version
  • RS-485 digital output
  • 4-20 mA output product version available

POR (price on request)

* Minimum order value: from 7 700 USD

SPECIFICATIONS

of ZET 7012-I VER.2 digital gauge pressure

Metrological performance
Measured value overpressure
Measurement error (from the measurement range) 0,1% 0,2%
Upper limit of pressure measurement range 0,1 MPa; 0,16 MPa; 0,25 MPa; 0,4 MPa; 0,6 MPa; 1 MPa; 1,6 MPa; 2,5 MPa; 4 MPa; 6 MPa; 10 MPa; 16 MPa; 25 MPa; 40 MPa; 60 MPa; 80 MPa; 100 MPa; 160 MPa
Resolution 0,005 %
Additional measurement error (depending on temperature changes) 0,1 %/10°C
Technical specifications
Refresh rate 1 Hz
Digital interface
Data interface RS-485
Data rate 4800, 9600, 14400, 19200, 38400, 57600, 115200 bps
Parity control 0 – no control; 1 – control (oddity, ODD)
Data communication protocol Modbus RTU
Analog interface*
Current signal 4-20 mA
Load resistance 0…250 Ohm
Operational parameters
Dimensions ∅31.5×160 mm ∅25×162 mm
Weight 380 g
Device power from 9 to 24 V
Power consumption 0,5 W
Polarity reversal protection yes
Operation temperature range from -40 to +100 °C
Operational environment liquids and gases compatible with titanium alloys and stainless steels
Product versions Standard (protection IP63)
Explosion-proof* (explosion protection 1ExdIIAT6X, cable length – 4 m)
Pressure overload 1,5×Upper measured pressure range
Electromagnetic compatibility EMC
(IEC 61000-4-2), ESD contact 4 kV; air 8 kV
(IEC 61000-4-4), EFT power 0,5 kV; signal 0,25 kV
(IEC 61000-4-5), Surge 500 V


*Option

Function

of ZET 7012-I VER.2 digital gauge pressure

Digital gauge pressure ZET 7012-I VER.2 is used in automated control systems and technological processes control systems in various industrial spheres:

  • oil and gas industry;
  • metallurgical industry;
  • energy industry;
  • construction engineering sector;
  • construction industry;
  • food manufacturing industry;
  • communal services and water supply industry;
  • automobile transport and shipping facilities.

The digital gauge pressure is used for fast measuring of pressure and transfer of the data obtained in digital format via RS-485 or 4-20 mA interface .

Explosion proof character

Explosion protection certificate № 0038579

ZET 7012-I DIGITAL GAUGE PRESSURE MEETS CUSTOMS UNION TECHNICAL REGULATIONS “ON THE SAFETY EQUIPMENT FOR WORKING IN HAZARDOUS ENVIRONMENTS” TP TC 012/2011

OPERATING PRINCIPLE

of Digital gauge pressure ZET 7012-I VER.2

ZET 7012-I VER.2 digital gauge pressure consists of primary transducer and integrated measuring module.

Primary transducer converts pressure values into analog signal. The measuring module converts the signal from the transducer into digital format and transfers the pressure readings via RS-485 (Modbus protocol) or via “Current loop” interface (4-20 mA).  The membrane of the primary transducer is made of elastic silicon plate. This allows to perform inertia-free dynamic measurements with duration up to 1 ms. Unlike metal plates with fixed bridge strain gauges, membranes of this type enable registering pressure fluctuations at the level of 0,00005 from the upper range limit.

ZET 7012-I VER.2 digital gauge pressure has an integrated cable. Depending on the product version specfication, the sensors are delivered whether with contact output for the interface 4-20 mA, or for RS-485, or with a plug FQ14-7TJ-8 at the end of the cable for connection to the interfaceRS-485 (connection to the measuring network should be performed via ZET 7002 converter).

The pressure meters are mounted on the controlled object and interface modules providing data transfer are placed inside of electrical cabinets.

INSTALLATION REQUIREMENTS

for ZET 7012-I VER.2 digital gauge pressure

The pressure transducers should be installed in the corresponding mounting seats, connectors, weldolets, etc.

Mounting of the pressure transducer (installation into the mounting seat) is to be conducted with the use of wrench and hex connection. It is not allowed to use any other parts of the transducer package for installation purposes.

In order to ensure hermeticity of the transducer at the installation site, use the sealing end (paronite gasket).

Use of other sealing instruments (foam tape, linen fiber, etc.) is forbidden, since it may damage the sensing membrane. In this case, installation of the transducer is conducted in enclosed volume, thus creating excessive pressure, which may exceed the operating range of the transducer.

Installation requirements Figure 1

Installation requirements Figure 2

Digital pressure meters: contacts layout

for connection to the interface 4-20 mA and RS-485

New connection scheme

Color  Labelling Designation
Red 1 +(9…24) V
Blue 2 RS-485 line «B» or «DATA -»
Green 3 RS-485 line«A» or «DATA +»
Yellow 4 GND
Pale green 5 Current+
Pale green 6 Current –

MEASURING NETWORK DIAGRAM

based on Digital gauge pressure ZET 7012-I VER.2

Using digital pressure meters is especially convenient when establishing distributed measuring networks. Unlike normally used centralized measuring networks, there is no need to use “star-type” conection, which allows to  reduce overall cable length. Since the data is transmitted in digital format, the are less requirements for data transfer channel, besides, one can use inexpensive cables for the network establishing.

In order to connect the measuring network to ZETLAB and ZETVIEW systems, one can use interface converter ZET 7070 (USB ↔ RS-485) or ZET 7076 (Ethernet ↔ RS-485). Using inner power supply module ZET 7070 one can connect up to 4 digital pressure meters to a single ZET 7070 module (and up to 60 digital pressure meters if external power supply module is used).

Scheme of measuring network 7XXX-RS-485

ZETLAB Software enables connection of up to 1024 sensors to a single PC. Measuring networks can also be connected to any system using Modbus protocol via interface RS-485.

Connection scheme of pressure transducers with current output is shown in the figure below:

New connection scheme

Pb_free
Directive 2011/65/EU (ROHS, ROHS II)

DIGITAL PRESSURE GAUGE METERS MEET THE REQUIREMENTS OF DIRECTIVE 2011/65/EU (ROHS, ROHS II) CONCERNING LIMITATION TO USE HAZARD SUBSTANCES (PB, HG, CD, CR(VI)) IN ELECTRICAL AND ELECTRONIC EQUIPMENT; THEY ARE MANUFACTURED USING LEAD-FREE METHOD, IN COMPLIANCE WITH THE EUROPEAN COMMUNITY REQUIREMENTS

RoHS-Comliance

BASIC CONFIGURATION

of Digital gauge pressure ZET 7012-I VER.2

Digital-gauge-pressure-ZET-7012-I-VER

Basic configuration of digital gauge pressure meter includes:

  • digital gauge pressure ZET 7012-I VER.2;
  • coupling unit of measuring line ZET 7001;
  • paronite gasket;
  • set of operational documentation.

Order form - If you want to place an order or to make a request regarding technical specifications of particular product, fill out the form below:

Data protection notification

Please note that the personal data provided by you is used exclusively for the purposes of fulfilling our contractual obligations, including, but not limited to: issuing invoices, delivery documents, documentation relating to customs clearance process, etc. We do not provide your personal data to any third party except for the purposes relating to our direct contractual obligations. Upon completion of order processing and expiry of the warranty period for the Products provided by our Company, we do not store or process any of your personal data. Please note, that our Company’s Confidential policy does not imply any advertising or marketing activities with the use of your personal data (including your Company name, address, your E-mail, phone number and other information provided by you with a view to placing an Order and organization of the Delivery).

NECESSARY MEASURING PRODUCTS

supplied upon request

Interface converter ZET 7076 Ethernet Wi-Fi RS-485
ZET 7076 Interface converter
Ethernet connection