Digital port ZET 7060

  • Logical analyzer
  • Digital input/ output, 4 bits, 0/5 V
  • RS-485 interface

POR (price on request)

* Minimum order value: from 7 700 USD

Specifications

of digital ports ZET 7060

Technical specifications
Number of channels (set as input/output) 4
Signal level 5 V
Data frequency 1, 10, 50, 100, 200 Hz
Data interface RS-485
Data rate 4800, 9600, 14400, 19200, 38400, 57600, 115200 bit/s
Parity control 0 – no control, 1 – control (oddity, ODD)
Data communication protocol Modbus RTU
Operational parameters
Dimensions 71×39×17 mm
Weight 30 g
Device power  7 – 24 V
Power consumption 0,5 W
Polarity reversal protection yes
Operation temperature range from -40 to +100 °C
Electromagnetic compatibility, EMC
 (IEC 61000-4-2), ESD contact 4 kV, air 8 kV
 (IEC 61000-4-4), EFT power 0,5 kV, signal 0,25 kV
 (IEC 61000-4-5), Surge 500 V
  • Digital port operation

    Each digital port operates independently from the others. “Shortcuts” for operation with digital ports via  ZETVIEW SCADA System.

  • "Autoports" operation

    4 autoports available for user configuration. The autoports can react to changes in signal level of other sensors, to impulses or a signal from user’s device.

  • Product versions

    Standard: laboratory version – green plastic casing
    OEM: compound coating
    Industrial*: standard module placed inside of a leak-proof casing with a transparent cover.
    *Option

Pb_free
Directive 2011/65/EU (ROHS, ROHS II)

DIGITAL MODULES MEET THE REQUIREMENTS OF DIRECTIVE 2011/65/EU (ROHS, ROHS II) CONCERNING LIMITATION TO USE HAZARD SUBSTANCES (PB, HG, CD, CR(VI)) IN ELECTRICAL AND ELECTRONIC EQUIPMENT; THEY ARE MANUFACTURED USING LEAD-FREE METHOD, IN COMPLIANCE WITH THE EUROPEAN COMMUNITY REQUIREMENTS

RoHS-Comliance

Operating principle

of digital ports ZET 7060

Digital port ZET 7060/ logical analyzer with RS-485 interface.

Function: control of the connected devices. Used in control and automation systems.

For the connection of the control modules to ZETLAB and ZETVIEW systems interface converter ZET 7070 (USB connection) or ZET 7076 (Ethernet connection) are used.

Measuring network connection scheme

of digital ports ZET 7060

The number of sensors connected to ZET 7070 module in the case of integrated power supply module ZET 7070 usage is not more than 4. In the case of external power supply module use the number of connected sensors is up to 60. ZETLAB Software enables connection of up to 1024 modules to a single PC.

Control modules can also be connected to any system using Modbus protocol via RS-485.

Control modules can be equipped with digital sensors for the purpose of feedback communication.

Controlled device connection side

Contact Designation Labelling
1 Ground GND
2 Control signal D3 D3
3 Control signal D2 D2
4 Control signal D1 D1
5 Control signal D0 D0
6 Power 5 V 5 V

Designation of output connectors for connection to the line RS-485

Contact Designation Labelling
1 +(9…24) V Orange
2 RS-485 line «B» or «DATA-» Blue
3 RS-485 line «A» or «DATA+» White-blue
4 GND White-orange

Basic configuration

of Digital port ZET 7060

Standard equipment

Digital port basic configuration includes:

  • Digital port ZET 7060;
  • DIN-rail mounting panel for plastic modules 71×39;
  • set of operational documentation.

POR (price on request)

* Minimum order value: from 7 700 USD

Order form - If you want to place an order or to make a request regarding technical specifications of particular product, fill out the form below:

Data protection notification

Please note that the personal data provided by you is used exclusively for the purposes of fulfilling our contractual obligations, including, but not limited to: issuing invoices, delivery documents, documentation relating to customs clearance process, etc. We do not provide your personal data to any third party except for the purposes relating to our direct contractual obligations. Upon completion of order processing and expiry of the warranty period for the Products provided by our Company, we do not store or process any of your personal data. Please note, that our Company’s Confidential policy does not imply any advertising or marketing activities with the use of your personal data (including your Company name, address, your E-mail, phone number and other information provided by you with a view to placing an Order and organization of the Delivery).

Necessary measuring equipment

supplied upon special order

Interface converter ZET 7076 Ethernet Wi-Fi RS-485
ZET 7076 interface converter
Ethernet connection